11 ALARM MANAGEMENT

Failure is signalled by means of the following procedure:
1) sound warning (beep),
2) lighting up of one of the following icons:
3) in the case of an alarm, the stove will be extinguished,
4) holding the "cancel" button
the alarm:
CODE OF
ALARM/
MESSAGE
E001
E002
E004
E101
E105
*
E108
E109
E110
E111
A001
A002
A004
A007
----
----
* Only in the case of models equipped with safety micro-switches in the door or on the container's cover.
After
the
message
checked, the alarm can
be cleared by pressing
the
ignition/extinguishing
button
for
seconds.
16
displays the code of
DESCRIPTION
Control keyboard damaged
Remote control signal not received
Connection interrupted
Ignition failed
Pellet sensor alarm
Safety alarm
Pressure alarm or tripping of circuit
breaker
Malfunction of temperature sensor
Malfunction of smoke sensor
Insufficient pellet level (flashing icon)
Warning concerning planned
maintenance (flashing icons)
Low battery
Malfunction of pressure sensor
(flashing icon)
Cleaning the stove
Ignition failed
is
several
,
POTENTIAL CAUSES
Damage to control keyboard
Damage to control keyboard
Cutting off or disconnection of cable connecting
the card to the control keyboard.
Ignore this alarm if it is displayed during change of
configuration.
No pellet
Pellet quality
Malfunction of ignition system
Dirty brazier
Pellet sensor damaged or disconnected
Open door or funnel
Dirty smoke extraction system
Wear of gaskets
Insufficient air for combustion
Overheating of pellet container
Damaged air sensor
Damaged smoke temperature sensor
Pellet running out
The stove requires regular maintenance, which
must be performed by specialised personnel.
The back-up battery (mod. CR2032) on the
electronic board is low
Malfunction of pressure sensor or card
Dirty combustion chamber, brazier or smoke
extraction system.
Pollution or disconnection of pressure reading
cables.
Pollution of inlet for combustion air.
No pellet; igniter damaged; worn gasket; improper
brazier positioning
If code "E109" is displayed, manually restart the thermostat
located on the rear of the stove, then clear the alarm (fig. 11.1)
(this activity must be performed according to the guidelines
of the authorised seller). The stove can be reignited..
fig� 11�1