5. IMPORTANT: This step must be the last step you perform on the master

Installing the support rails for the SAN Volume Controller

You must install the support rails that hold the SAN Volume Controller.
Before you install the support rails, perform the following tasks:
v Determine where the SAN Volume Controller is to be installed in the rack.
v Refer to the Electrical Industries Association (EIA) markings on the rack and
Perform the following steps to install the support rails:
Figure 43. Retracting the latch lock carrier
66
IBM System Storage SAN Volume Controller: Installation Guide
console before handing over the machine; it sets up the master console to
present a Windows license agreement screen at the next power on and then
shuts down the master console.
a. Select Start → Run
b. Type c:\sysprep\sysprep.exe
c. Click OK.
Note: It is important that you do this step; otherwise, the user is not presented
with the choice to accept or decline Windows registration conditions.
Related reference
Chapter 3, "Master console," on page 45
The SAN Volume Controller provides a master console that can be used as a
single platform to configure, manage, and service the SAN Volume Controller.
decide where you are going to install the support rails.
1. Check the labels on the support rails. Each rail has a label that indicates which
is the front end of the rail and whether the rail is for the left or right side of
the rack. Perform this procedure for both rails.
2. Put your index finger against the side of the latch-lever,
put your thumb against the front of the latch-lock
2
1
1
Latch-lever
2
Latch-lock
1
in Figure 43, and
2
.