Node Number; Ethernet Mode - IBM 2145-8F4 Installation Manual

System storage san volume controller
Table of Contents

Advertisement

|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
N o d e :
x x x x x x
Figure 54. Node number
7. Press and release the up or down button until the Ethernet option is shown
on the front panel display. The second line of the front-panel display in
Figure 55 shows the message Inactive. This message shows that, although an
Ethernet connection is available, it cannot yet be used.
E t h e r n e t :
I n a c t i v e
Figure 55. Ethernet mode
8. Press and release the up or down button until the FC Port-1 option shows in
the display.
9. Check whether the second line of the front-panel display shows the message
Active. If Active is not shown on the second line, go to the fibre-channel
MAP to repair the fault.
10. If you are installing a SAN Volume Controller 2145-4F2 or a SAN Volume
Controller 2145-8F2, go to step 16. If you are installing a SAN Volume
Controller 2145-8F4, go to step 11.
11. Press and hold the down button.
12. Press and release the select button.
13. Release the down button. The operational speed of the fibre-channel link is
displayed. Use the cable connection table that is provided by the customer to
verify that the fibre-channel link is operating at the expected speed. If the
operational speed does not match the expected speed, go to the fibre-channel
MAP to repair the fault.
14. Press the select button to return to the fibre-channel status display.
15. Press the right button to display each port in turn and repeat the above speed
check. Go to step 18
16. Press and release the left or right button to display the other port options.
Check whether for each port, the second line of the front-panel display shows
the message Active. If Active is not shown for any port, go to the
fibre-channel MAP to repair the fault.
17. If the configuration data table provided by the user indicates that the SAN
Volume Controller nodes are to be operated at 1 Gbps, follow these steps:
a. Press and hold the down button.
b. Press and release the select button.
c. Release the down button.
The second line of the front-panel display shows the current fibre-channel
speed setting of the node. Press the up or down button until 1 Gbps is
displayed and then press the select button. This changes the fibre-channel
speed for all ports on this node to 1 Gbps.
18. If you want to select a language other than English, perform the following
steps:
a. Press the up or down button until Select Language? is displayed.
Chapter 4. Installing the UPS, the master console, and the SAN Volume Controller
77