Checking the grounding of the SAN Volume Controller
|
2145-8F4 and the 2145 UPS-1U
|
|
|
|
|
|
5. Check inside the SAN Volume Controller for any obvious unsafe conditions,
such as metal particles, contamination, water or other fluids, or marks of
overheating, fire, or smoke damage.
6. Check for worn, damaged, or pinched cables.
7. Ensure that the voltage that is specified on the product-information label
matches the specified voltage of the electrical power outlet. If necessary, verify
the voltage.
8. Inspect the power supply assemblies and check that the fasteners (screws or
rivets) in the cover of the power-supply unit have not been removed or
disturbed.
9. Before connecting the SAN Volume Controller to the SAN, check the
grounding.
External machine check
Ensure that you perform an external machine check before you install the SAN
Volume Controller.
Perform the following steps to conduct an external machine check:
1. Verify that all external covers are present and are not damaged.
2. Ensure that all latches and hinges are in the correct operating condition.
3. If the SAN Volume Controller is not installed in a rack cabinet, check for loose
or broken feet.
4. Check the power cord for damage.
5. Check the external signal cable for damage.
6. Check the cover for sharp edges, damage, or alterations that expose the internal
parts of the device.
7. Correct any problems that you find.
Internal machine checks
Ensure that you perform an internal machine check before you install the SAN
Volume Controller.
Perform the following steps to conduct the internal machine check:
1. Check for any non-IBM changes that might have been made to the machine. If
any are present, obtain the "Non-IBM Alteration Attachment Survey," form
number R009, from the IBM branch office. Complete the form and return it to
the branch office.
2. Check the condition of the inside of the machine for any metal or other
contaminants, or any indications of water, other fluid, fire, or smoke damage.
3. Check for any obvious mechanical problems, such as loose components.
4. Check any exposed cables and connectors for wear, cracks, or pinching.
Ensure that you understand how to check the grounding of the SAN Volume
Controller 2145-8F4 and the 2145 uninterruptible power supply-1U (2145 UPS-1U).
Perform the following steps to ensure that the SAN Volume Controller 2145-8F4 is
properly grounded:
1. Ensure that all power is removed.