Verifying The San Volume Controller Installation; Connectors At The Back Of The San Volume - IBM 2145-8F4 Installation Manual

System storage san volume controller
Table of Contents

Advertisement

|
|
|
|
|
|
|
|
|

Verifying the SAN Volume Controller installation

5
Figure 52. Connectors at the back of the SAN Volume Controller 2145-8F4
1
Fibre-channel port 1
2
Fibre-channel port 2
3
Fibre-channel port 3
4
Fibre-channel port
5
Ethernet port 1
Attention:
When routing the fibre-channel cables, do not tighten the cable
straps or bend the cables to a radius smaller than 76 mm (3 in.).
2. Connect the fibre-channel cables to the fibre-channel ports as required by the
user's configuration.
3. Connect the other end of the Ethernet cable to the proper connector on the
Ethernet hub or switch.
4. Connect the other ends of the fibre-channel cables to the proper connectors of
the fibre-channel switches.
Related concepts
"SAN Volume Controller menu options" on page 82
Menu options are available on the front panel display on the SAN Volume
Controller.
Related reference
"SAN Volume Controller controls and indicators" on page 5
All controls and indicators are located on the front panel of the SAN Volume
Controller.
"Ethernet option" on page 88
The Ethernet option displays the operational states of the Ethernet port and its
media access control (MAC) address.
You must verify the SAN Volume Controller installation after the installation has
completed.
This task shows you how to verify the installation after you install the SAN
Volume Controller in the rack and connect it to both the uninterruptible power
supply and the storage area network (SAN).
Perform the following steps to verify installation:
Chapter 4. Installing the UPS, the master console, and the SAN Volume Controller
1
2
3
4
75