Figure 35. 10 Gbps Ethernet ports on the rear of the SAN Volume Controller 2145-CG8
4. Connect the Fibre Channel cables to the Fibre Channel ports as required by the
5. Connect the other ends of the Fibre Channel cables to the proper connectors of

Verifying the SAN Volume Controller 2145-CG8 installation

You must verify the SAN Volume Controller installation after the installation has
completed.
Before you begin
This task shows you how to verify the installation after you install the SAN
Volume Controller in the rack and connect it to the uninterruptible power supply,
the storage area network (SAN), and the Ethernet.
Note: If at any point the SAN Volume Controller does not operate as described,
see MAP 5000 in the IBM System Storage SAN Volume Controller Troubleshooting
Guide, unless a different maintenance analysis procedure (MAP) is specified.
About this task
Perform the following steps to verify installation:
Procedure
4 Fibre Channel port 4
5 Power-cord connector for power supply 1
6 Power-cord connector for power supply 2
7 Serial connection for UPS communication cable
8 Ethernet port 2
9 Ethernet port 1
1 10 Gbps Ethernet port 3
2 10 Gbps Ethernet port 4
Attention:
When routing the Fibre Channel cables, do not tighten the cable
straps or bend the cables to a radius smaller than 76 mm (3 in.).
user's configuration.
the Fibre Channel switches.
1. Press the SAN Volume Controller power-control button. Because the button is
recessed, you might need a pointed device, such as a screwdriver, to press the
power-control button. Verify that the green power LED is lit. If the LED is not
illuminated, see MAP 5000: Start in the IBM System Storage SAN Volume
Controller Troubleshooting Guide to repair the problem.
Note: You do not need to install any software. The node boots automatically.
Chapter 2. Installing the SAN Volume Controller 2145-CG8 hardware
1
2
39