Peripheral Devices and Options

The following tables show the available peripheral devices and options for the drive. Contact Yaskawa or your
nearest sales representative to place an order.
• Selection: Refer to the drive catalog for information about available products.
• Installation and wiring: Refer to the instruction manual for each option.
Name
DC Reactor
UZDA series
AC Reactor
UZBA series
Braking Resistor
ERF-150WJ Series
Braking resistor with fuse CF120-B579 Series
Braking Resistor Unit
LKEB series
Braking Unit
CDBR series
Molded-Case Circuit
NF series
Breaker (MCCB)
Earth Leakage Circuit
NV and NS series
Breaker (ELCB)
Input Side Magnetic
SC series
Contactor (MC)
200 V class: DCR2-xA
Surge Protective Device
400 V class: RFN3AL-
504KD
YASKAWA ELECTRIC SIEP C710617 19A YASKAWA AC Drive CR700 Technical Manual
Dimensions mm (in.)
D1
D2
D3
117
56
-
(4.61)
(2.20)
(3.07)
124.8
117.3
61.8
(4.91)
(4.62)
(2.43)
(3.78)
208.4
166.3
75.3
(8.20)
(6.55)
(2.96)
(3.65)
170
66.6
-
(6.69)
(2.62)
(5.71)
Table 9.16 Main Circuit Option
Model
To improve the drive input power factor.
• To prevent damage to the drive when the power supply capacity is large. You
must only use this option when the power supply capacity is more than 600
kVA.
• To decrease harmonic current.
• To improve the power supply total power factor.
To improve the drive input power factor.
• To prevent damage to the drive when the power supply capacity is large. You
must only use this option when the power supply capacity is more than 600
kVA.
• To decrease harmonic current.
• To improve the power supply total power factor.
To decrease the regenerative energy of the motor and decrease the deceleration
time (duty cycle of 3% ED). You must also use the installation attachment.
To decrease the regenerative energy of the motor and decrease the deceleration
time (duty cycle of 3% ED). You must also use the installation attachment.
To decrease the regenerative energy of the motor and decrease the deceleration
time (duty cycle of 10% ED). The unit contains a thermal overload relay.
Use with a braking resistor unit to decrease motor deceleration times.
To prevent short circuit damage to the power supply system and provide overload
protection for wiring.
To prevent short circuit damage to the power supply system, provide overload
protection for wiring, prevent electrical shock, and provide ground fault protection
against earth leakage fires.
Note:
• You can use a molded-case circuit breaker as a replacement for an ELCB that
is upstream in the power supply system.
• When you use a high frequency ELCB at the power input side of the drive,
make sure that each drive has a minimum cumulative sensitivity amperage of
30 mA.
To prevent burn damage when connecting a braking resistor. This option fully
opens the circuit between the power supply and drive.
To absorb open/close surges from the magnetic contactor and control relay. You
must connect this option to magnetic contactors, control relays, magnetic valves,
or magnetic brake coils.
W
W1
W2
φd4
78
37.5
-
(1.48)
(1.73)
96
61.5
-
(2.42)
(1.97)
92.8
27.5
-
(1.08)
(1.38)
145
40
120
(1.57)
(4.72)
(1.38)
Purpose
9 Specifications
φd5
φd6
44
35
62
(1.38)
(2.44)
50
35
75
(1.38)
(2.95)
35
62
-
(2.44)
35
75
-
(2.95)