13-3-2 Relating to the I/O

No.
Symptom
1
Output signal
cannot be
controlled.
* In cases other
than cause 2,
the output
signal cannot
be controlled
even with the
manual
instruction of
TPB general-
purpose output.
2
Robot will not
move even
with dedicated
command
input.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Possible Cause
Items to Check
1)
Motor and/or
• Check the motor wire and resolver
resolver are
signal wire connections.
miswired.
2)
Parameter error
1)
Parameter setting
• Check whether the robot setting
error
displayed on the TPB matches the
robot actually used.
2)
Speed setting was
• Check the speed parameter (PRM17).
changed.
Possible Cause
Items to Check
1)
Wiring to external
• Check the wiring.
devices is
• Check the operation with the manual
incorrect.
instruction of the TPB general-purpose
output. (Refer to "7-4 Manual Control
of General-Purpose Output".)
2)
Misprogramming
• Connect the TPB and check the
program.
3)
Output transistor
• Measure the voltage at the PLC input
is defective.
terminal.
ON: 0.5V or less
OFF: +IN COM (+24V)
Return-to-origin
• Connect the TPB and check the
1)
has not yet been
operation.
completed.
Program cannot be
• Connect the TPB and check the
2)
run.
operation.
Signal pulse width
• Check that the signal pulse width is
3)
is too narrow.
50ms or more.
4)
Time interval
• After canceling emergency stop, allow
before inputting a
at least 200ms before inputting a
dedicated command
dedicated command before inputting a
after canceling
dedicated command.
emergency stop is
too short.
5)
Interlock signal
• Check the signal by using the TPB DIO
remains off.
monitor.
Another dedicated
• Check the signal input (by using a PLC
6)
command input is
monitor, etc.).
on.
13-3 Troubleshooting for Specific Symptom
Action
• Correct the connections.
• Try Initialize the parameters.
• If they do not match, initialize the
parameters.
• Correct the parameter.
Action
• Make the correct wiring by referring to
the connection diagram.
• Change the program.
• Replace the DRCX controller if the
output transistor is defective.
• Reperform return-to-origin.
• Eliminate the cause of error by
referring to the error message.
• Increase the signal pulse width ("on"
duration).
• Increase the delay time.
• Switch on the interlock signal.
• Turn off the dedicated command input.