5-2 Parameter Description
5
28
5-
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
PRM121:Deceleration (Available with Ver. 18.25 or later)
Use this parameter to reduce only the deceleration.
When this parameter is left set to the default value (100), the deceleration is the same as
the acceleration. If vibration occurs during positioning, then set this parameter to a smaller
value to reduce only the deceleration.
This parameter value can be changed in 1% steps, with 100% equal to the value deter-
mined by PRM91.
Input range:
1 to 100 (%)
Default value: 100
PRM122:Hold gain (Available with Ver. 18.50 or later)
Default value: Depends on the robot.
PRM123:Not used
Default value: 0
PRM124:Not used
Default value: 0
PRM125:Not used
Default value: Depends on robot type.
c
CAUTION
Do not change the setting.
PRM126 to 127: Spare