Error Code Definition Table (Continued)
Error code
11,004.4x
ECM_LHCF_SER_LINK_BROK
EN
11,005.4x -
ECM_FP_SER_LINK_BROKEN
11,006.4x -
ECM_IO_SER_LINK_BROKEN
11,007.4x -
ECM_PCTL_SER_LINK_BROK
EN
11,008.4x -
ECM_HEAD_SER_LINK_BRO
KEN
12,000.6x - ITC_PROG_FAULT no description
3-20
Definition
Upper feeder broken serial link detected. This indicates
that 7 consecutive frames occured with errors.
1.
Ensure all ground straps and ground planes are
intact.
2.
Reset NVRAM and retest.
3.
Inspect all data wiring harness.
FP broken serial link detected. This indicates that 7
consecutive frames occured with errors
1.
Ensure all ground straps and ground planes are
intact.
2.
Reset NVRAM and retest.
3.
Inspect all data wiring harness.
FP broken serial link detected. This indicates that 7
consecutive frames occured with errors.
1.
Ensure all ground straps and ground planes are
intact.
2.
Reset NVRAM and retest.
3.
Inspect all data wiring harness.
Power Control broken serial link detected. This indicates
that 7 consecutive frames occured with errors.
1.
Ensure all ground straps and ground planes are
intact.
2.
Reset NVRAM and retest.
3.
Inspect all data wiring harness.
Head broken serial link detected. This indicates that 7
consecutive frames occured with errors.
1.
Ensure all ground straps and ground planes are
intact.
2.
Reset NVRAM and retest.
3.
Inspect all data wiring harness.