DME Setup
Settings Relating to
Signal Inputs

Setting Initial Crop

1
In the <Aspect> group of the Engineering Setup
>DME >Input menu (7341), select the screen aspect
ratio (16:9 or 4:3).
2
In the DME1 <Crop> group, press [Initial Crop] and
set the following parameters.
No.
Parameter Adjustment
1
Top
Position of top side
2
Left
Position of left side
3
Right
Position of right side
4
Bottom
Position of bottom side
To return the settings to the defaults
In the <Crop> group, press [Unity].
Setting the Illegal Color Limiter for
Matte Signals
Enable/disable the illegal color limiter for the signal
generated by the DME internal matte generator.
To enable, in the Engineering Setup >DME >Input menu
(7341), press [Matte Illeg Col Limit] for DME1, turning it
on.