3-14
Measurement - Machine template
Template for 'Production test'
and selection of the meas. task
Number of measurements
(here: 2 / 1 / 0)
'Production test' option
in the OMNITREND template editor

Preliminary remarks

In principle, a machine template is set up like a route and resembles
a route in operation and workflow (see previous section). The
differences to a route are described in the following points:
Machine description
This must be identified with a name before the first measurement.
Additional data for documentation purposes (such as serial number,
model, customer, and tester) can also be entered.
Production test
During a production test, the automatic call up of the next
measurement task is deactivated. In this way it is possible to carry
out the same measurement task under different operating conditions
within the scope of a production test. The remaining measurement
tasks are called up manually.
To create a template for a production test, the 'Production test'
option must be activated in the OMNITREND template editor (see
below).
In the case of templates for production tests, the measurement
location hierarchy on the machine is only shown in the tree view.
A list view is not available. The number of measurements carried
out for each measurement location and measurement task appears
instead of the status information.
Number of measurements per task
(in this case: 1.0 = 3 meas. / 3 tasks)