3-8
Measurement - Route
Aggregates und machines in the tree
view (left) and in the machine graphic
view mode (right).
Measurement tasks in the route
Route in tree view / list view
Reverse path to meas. location
Measurement channel and sensor
Notes about the tree view:
- If the 'Graphic Route' option is activated (p. 2-14), you can select
the measurement location using the machine graphic.
Note
- If the branch cannot be opened up to the measurement location
level, press the MENU key and select 'Expand' -> 'Meas. points'
(see below).
Notes about the list view:
- The list view only shows the measurement locations.
- The order of the measurement locations in the list view can vary
from the order in the tree view. The list view indicates the order of
the route. The tree view indicates the sequence in the measure-
ment location database.
Standard sensor is active when the sensor icon at the top right is
orange and the sensor type in the info field is marked red! The sen-
sor setup is overwritten with the standard sensor. (p.3-3).
Attention!
Reference measurements must be carried out first (e.g. RPM mea-
surement for the normalization of a bearing measurement).
Various route options shorten the measurement times. Depending
on which option is enabled in the Route Setup, the measurements
Note
can take place virtually automatically (see also p. 2-16).
Left:
Right:
Centrifugal pump
Motor