The configuration screen appears (see below).
Start conditions
Immediately: The recording starts immediately (MENU -> Start).
Start in: The measurement recording begins after a set period (0 s ...
23:59:59 h).
Start at: The measurement recording begins at the set time
(time, date) or when the set rpm is reached (0 ... 1000 Hz);
rising or falling edge can be selected. For an rpm-controlled
measurement, the task must contain an rpm measurement.
Delay: Specifies the time/rpm change between two measurements.
Stop conditions
Counter: The measurement is ended when the entered number of
results has been measured (1 ... 10000).
Run for: The measurement recording runs for the specified time (0 s
... 23:59:59 h).
Stop at: The measurement stops at the specified time or when the
set rpm is reached (0 ... 1000 Hz); the rising or falling edge can
be selected.
Manual: The measurement stops when the memory card is full or
when the ESC key is pressed.
Further settings
Switch off backlight: To save power when operating the device
during recording, the display illumination can be switched off
permanently. This option is independent of the settings in the
device setup (P. 2-13).
Trigger: This option is only available if the measurement is triggered
via the signal level (see 'Trigger', p. 3-22).
'Single': The trigger condition is only considered before the first
measurement.
'Multi': Only start each measurement when the trigger condition
has been met.
Target file: The results and the configuration settings are saved in a
file. It is not possible to add multiple recording files.
The start, stop and delay
conditions can be independently
controlled according to time or
rpm. For example, recording can
be set to start at a certain time,
but the next measurements only
take place after a certain change
in the rpm.
Recording
Recording configuration
The number of results depends on the
available memory space
3-37