Fluke VIBXPERT II User Manual page 28

Data collector & vibration analyzer
Hide thumbs Also See for VIBXPERT II:
Table of Contents

Advertisement

- Enabled: Display of machine images. The position of the
measurement locations and the measurement direction is
indicated by symbols.
- Disabled: The route is processed in the set display mode (tree /
list)
Display all hierarchies
This option applies to the tree view only.
- Enabled: The tree displays all hierarchy levels.
- Disabled: The tree only opens the branch with the first non-
measured measurement location.
Hide measured/ skipped hierarchies
This option applies to the tree view only.
- Enabled: Measured/skipped hierarchy levels are hidden in the
tree.
- Disabled: Measured/skipped hierarchy levels are displayed in
the tree.
Jump to next unmeasured (measurement location)
Here you can define to which measurement location the cursor
should jump after you view a stored result and close the
measurement task selection window.
- Activated: the cursor jumps to the next unmeasured measurement
location.
- Disabled: the cursor remains on the current measurement
location.
Active Hierarchy/ Mode
The following settings determine how the tree structure should
appear when opening the route / machine template:
- Train / Machine / Measurement location: The tree opens to the
selected hierarchy level*.
- Auto: Dynamic adaptation of the tree view. The type of display
depends on whether the route contains graphical information
and whether the 'Graphic Route' option is enabled.
Show result
With every measurement task, older, historic measurements can
be saved in the route and called up to compare them with current
results.
- Standard: last measurement saved.
- History: last measurement saved and historical data.
Getting started - Basic settings
The route is set up hierarchically ac-
cording to the following plan:
1. Database - highest hierarchy
2. Location - factory, plant, customer
3. Train - groups of machines
4. Machine - individual machines
5. Measurement location - position of
the measurement location
6. Measurement task - e.g. vibration
acceleration
2-15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vib 5.310

Table of Contents