4.2 Settings in FUN Mode

In FUN mode, settings regarding measurement and recording of the unit are made.

4.2.1 List of setting items

The list below shows the setting items in FUN mode.
Display item
CYCLE
MEAS
MODE
REC
INIT
RESTR
BCKUP
YEAR
MONTH
TIME
(DISP)
DAY
CLOCK
IP1 to
IP4
IP
SUB1 to
(DISP)
SUB4
SDISP
Display
Setting item
Measurement
value update
cycle
Processing
mode
Measurement
operation mode
Measurement
value update
cycle
Recording mode CONT / RING
Return to
factory default
Read the setting
data from the
SD memory
card.
Write the setting
data into the SD
memory card.
Year
Month
Day
Hour: Minute
IP address
Subnet mask
Display mode at
sleep
4-2
4. Setting the Unit (Unit Operation)
Setting value
DPX21
1s (sec) / 2s / 5s / 10s / 20s / 30s /
1m (min) / 2m / 5m / 10m / 20m /
30m /1h (hour)
THX21
THX11
10s (sec) / 20s / 30s / 1m (min) /
2m / 5m / 10m / 20m /30m / 1h (hour)
NORM / MAX / MIN / AVE
DPX21
THX21
NET / SLEEP / PD-S
The unit is reset and restarted when
operation mode is changed with
MODE key after the setting values of
NET/SLEEP/PD-S is confirmed.
THX11
NORM / SLEEP
The unit is reset and restarted when
operation mode is changed with the
MODE key.
When holding the SET/REC/STOP
key, initialization starts. After "DONE"
is displayed and operation mode is
changed with the MODE key, the
unit is reset and restarted.
When inserting the SD memory
card and holding the SET/REC/
STOP key, the setting data is read
from the SD memory card and is
set to the main unit. When changing
operation mode with the MODE key
after DONE has been displayed.
The unit is reset and restarted.
When inserting the SD memory
card and holding the SET/REC/
STOP key, the setting data is saved
into the SD memory card.
Year setting
Month setting
Day setting
Hour/minute setting
DPX21
THX21
0 to 255
OFF / ON
Factory
default
10s
NORM
NET
NORM
CONT
-
-
-
Not
initialized
by INIT.
192.168.0.
20
255.255.2
55.0
OFF

Advertisement