Service and Repair Manual
Battery Charger
1 Error / Fault / USB indicator
2 Charger profile / Error display
3 Error / Fault
Charger Fault Codes
Charger Fault Codes
Fault Code
DC-DC failure: LLC excessive leakage
F-0-0-1
fault.
PFC failure: PFC excessive leakage
F-0-0-2
fault.
F-0-0-3
PFC taken too long to boost.
Charger unable to calibrate current
F-0-0-4
offset.
Output relay voltage too high when
F-0-0-5
closed.
180
Charger status indicators
Remote charger status indicators
Description
GS
™
-30 • 32 • 46 • 47
Possible Causes
Internal charger fault.
March 2021
Solution
Disconnect AC input and battery
pack for 30 seconds.
If fault does not clear, contact
Genie Product Support.
Part No. 1272217GT