Type "Fxxx" Faults - Terex Genie GS-1532 Service And Repair Manual

Hide thumbs Also See for Genie GS-1532:
Table of Contents

Advertisement

Service and Repair Manual

Type "FXXX" Faults

Type "FXXX" Faults
DTC
Message on
Number
GCON LCD
F001:
F001:SWITCHFAULT
GS-3232
UP LIMIT1:BAT+
F003:
GS30,
F003:SWITCHFAULT
GS32,
DOWN LIMIT1:BAT+
GS46 &
GS47
F005:
GS30,
F005:SWITCHFAULT
GS32,
POTHOLE:BAT+
GS46 &
GS47
F007:
GS30,
F007:SWITCHFAULT
GS32,
CHASSISTILT:BAT+
GS46 &
GS47
F008:
GS30,
F008:SENSORFAULT
GS32,
OVLD XDUCER:BAT+
GS46 &
GS47
F009:
GS30,
F009:SENSORFAULT
GS32,
OVLD XDUCER:BAT-
GS46 &
GS47
F010:
GS30,
F010:SENSORFAULT
GS32,
PLAT HEIGHT:BAT+
GS46 &
GS47
F011:
GS30,
F011:SENSORFAULT
GS32,
PLAT HEIGHT:BAT-
GS46 &
GS47
174
Description
Short circuit of the up limit #1 switch at
system startup.
Short circuit of the down limit #1 switch at
system startup.
Short circuit of the pothole limit #1 switch at
system startup.
Short circuit of the chassis digital tilt switch
at system startup.
Short circuit of the Platform Overload
Transducer circuit to battery positive.
Short circuit of the Platform Overload
Transducer circuit to battery negative.
Short circuit of the Platform Height Sensor
circuit to battery positive.
Short circuit of the Platform Height Sensor
circuit to battery negative.
GS
-30 • 32 • 46 • 47
Possible Causes
• Short circuit of the up limit switch circuit.
• Up limit #1 switch short circuit.
• GCON ECM.
• Short circuit of the down limit switch circuit.
• Down limit #1 switch short circuit.
• GCON ECM.
• Short circuit of the pothole switch circuit.
• Pothole limit #1 switch short circuit.
• GCON ECM.
• Short circuit of the chassis digital tilt switch
circuit.
• Chassis digital tilt switch short circuit.
• GCON ECM.
• Short circuit in the transducer circuit.
• Faulty pressure transducer.
• GCON ECM.
• Short circuit in the transducer circuit.
• Faulty pressure transducer.
• GCON ECM.
• Short circuit in the platform height circuit.
• Faulty platform height sensor.
• GCON ECM.
• Short circuit in the platform height circuit.
• Faulty platform height sensor.
• GCON ECM.
March 2021
Failure Mode
Platform up function
inhibited.
All functions inhibited
except platform down.
All functions inhibited
except platform down
as long as machine is
in the elevated
position. If machine is
in stowed position, all
functionality is
resumed.
All functions inhibited
except platform down
as long as machine is
in the elevated
position. If machine is
in stowed position, all
functionality is
resumed.
All functions inhibited.
All functions inhibited.
All functions inhibited
except platform down
as long as machine is
in the elevated
position. If machine is
in stowed position, all
functionality is
resumed.
All functions inhibited
except platform down
as long as machine is
in the elevated
position. If machine is
in stowed position, all
functionality is
resumed.
Part No. 1272217GT

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents