Lift Pressure Selector Manifold Components - Gs-4047 - Terex Genie GS-1532 Service And Repair Manual

Hide thumbs Also See for Genie GS-1532:
Table of Contents

Advertisement

March 2021
5-5
Lift Pressure Selector Manifold Components – GS-4047
The lift pressure selector manifold is mounted behind an inspection door, at the ground control side of the
machine.
Index No. Description
Coil nut (item DN)
Plug
Lift pressure selector valve, 200 psi /
1
138 bar
2
Solenoid valve, 2 position 2 way
Note: 'alpha' callouts refer to corresponding notes on the hydraulic schematic.
Note: 'alpha-numeric' callouts refer to corresponding notes on the electrical schematic.
How to Install a Valve Cartridge
1
Dip the cartridge in clean oil to lube the O-rings.
2
Screw the cartridge in by hand until the top O-ring is met, then torque to specifications.
3
If required, install the valve coil(s) onto the valve stem. Install the coil nut onto the valve stem and
torque to specifications.
Part No. 1272217GT
Schematic Item
DM
DN
GS
-30 • 32 • 46 • 47
Service and Repair Manual
Manifolds
Function
4-5 ft-lbs / 5-7 Nm
13 ft-lbs / 18 Nm
Lift relief
20 ft-lbs / 27 Nm
Lift circuit
20 ft-lbs / 27 Nm
Torque
61