Outrigger Function Manifold Components - Gs-3232 - Terex Genie GS-1532 Service And Repair Manual

Hide thumbs Also See for Genie GS-1532:
Table of Contents

Advertisement

Service and Repair Manual
Manifolds
5-6
Outrigger Function Manifold Components – GS-3232
The outrigger function manifold is mounted behind an inspection door, at the battery side of the machine.
Index No. Description
Coil nut (item BA)
1
Solenoid valve, 3 position 4 way
Relief valve, 3500 psi / 241 bar
2
maximum
Note: 'alpha' callouts refer to corresponding notes on the hydraulic schematic.
Note: 'alpha-numeric' callouts refer to corresponding notes on the electrical schematic.
How to Install a Valve Cartridge
1
Dip the cartridge in clean oil to lube the O-rings.
2
Screw the cartridge in by hand until the top O-ring is met, then torque to specifications.
3
If required, install the valve coil(s) onto the valve stem. Install the coil nut onto the valve stem and
torque to specifications.
62
Schematic Item
BA
BB
GS
-30 • 32 • 46 • 47
Function
4-5 ft-lbs / 5-7 Nm
Outriggers extend /
25 ft-lbs / 34 Nm
retract
Outrigger circuit
20 ft-lbs / 27 Nm
Part No. 1272217GT
March 2021
Torque

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents