3.8
Flue probe and safety thermal
fuse
If the flue thermal cut-off fuse is
triggered, the boiler goes into
safety lockout. To restore nor-
mal boiler operation, please
contact an Authorized Service
Centre.
The flue probe and safety thermal fuse 19
indicated in Fig. 3.7 are a safety device. The
flue probe 19 intervenes when the flue tem-
perature exceeds 110°C placing the boiler
in safety block switching it off.
To reset normal boiler functioning, just press
the 17 (Fig. 3.5) key.
If flue probe 19 does not intervene and,
therefore does not send the boiler into secu-
rity lockout, flue thermal fuse 19 is triggered
as an additional safety device to protect the
flue outlet pipe.
To restore the normal operation of the boil-
er, contact the Authorized Service Centre.