4.5
Technical data BASICA COND
32C (M275V.2832 SM)
Heat input
Nominal net
central heating
(A)
Nominal net
domestic hot water
(A)
Nominal gross
central heating
(B)
Nominal gross
domestic hot water
(B)
Minimum net
C.H. - D.H.W.
(A)
Minimum gross
C.H. - D.H.W.
(B)
Useful output
Maximum (central heating)
Maximum (domestic hot water)
Minimum (C.H. - D.H.W.)
Maximum condensing (central heating)
Maximum condensing (domestic hot
water)
Minimum condensing (C.H. - D.H.W.)
- 32 -
TECHNICAL INFORMATION
kW
27,5
BTU/h 93834
kW
32,0
BTU/h 109188
kW
30,5
BTU/h 104156
kW
35,5
BTU/h 121199
kW
6,2
BTU/h 21155
kW
6,9
BTU/h 23482
kW
27,0
BTU/h 92128
kW
31,3
BTU/h 106800
kW
5,8
BTU/h 19790
kW
29,9
BTU/h 102023
kW
34,8
BTU/h 118742
kW
6,6
BTU/h 22520
Central heating
Min/Max flow temperature settings*
Maximum pressure
Minimum pressure
Available head (in 1000 l/h)
* to the minimum useful output
referred to the net calorific value at 15 °C and
(A)
1013,25 mbar: G20 = 34,02 MJ/m
kg
referred to the gross calorific value at 15 °C and
(B)
1013,25 mbar: G20 = 37,78 MJ/m
kg
Domestic hot water
Min/Max temperature settings
Maximum pressure
Minimum pressure
Flow rate minimun
Flow rate 30° rise
(D)
Flow rate 35° rise
(D)
Flow rate 40° rise
(D)
Values subject to tolerance
(D)
Gas supply pressures
Gas
Nom
Natural G20
Min
Max
Nom
Propane G31
Min
Max
°C
25-85
kPa
250
bar
2,5
kPa
30
bar
0,3
kPa
38,5
bar
0,39
- G31 = 46,34 MJ/
3
- G31 = 50,37 MJ/
3
°C
30 - 60
kPa
1000
bar
10
kPa
30
bar
0,3
l/min
2,5
l/min
16,2
l/min
12,9
l/min
11,2
Pa
mbar
2000
20
1700
17
2500
25
3700
37
2500
25
4500
45