Biasi BASICA COND User Manual And Installation Instructions page 31

Table of Contents

Advertisement

Model(s):
Condensing boiler:
Low-temperature boiler (**):
B1 boiler:
Cogeneration space heater:
Combination heater:
Item
Rated heat output
For boiler space heaters and boiler combination heat-
ers: Useful heat output
At rated heat output and
high-temperature regime (*)
At 30% of rated heat output
and low-temperature regime
(**)
Auxiliary electricity consumption
At full load
At part load
In standby mode
For combination heaters:
Declared load profile
Daily electricity consumption
Annual electricity consump-
tion
Contact details
(*) High-temperature regime means 60°C return temperature at heater inlet and 80°C feed temperature at heater
outlet.
(**) Low temperature means for condensing boilers 30°C, for low-temperature boilers 37°C and for other heaters
50°C return temperature (at heater inlet).
TECHNICAL INFORMATION
No
Symbol Value
Unit
P
25
kW
rated
P
24,5
kW
4
P
8,2
kW
1
elmax
0,051
kW
elmin
0,014
kW
P
0,003
kW
SB
XL
Q
0,137
kWh
elec
AEC
30
kWh
BASICA COND 28C
If yes, equipped with a supplementary heater:
Item
Seasonal space heating
energy efficiency
Seasonal energy efficiency
class
For boiler space heaters and boiler combination heat-
ers: Useful efficiency
At rated heat output and
high-temperature regime (*)
At 30% of rated heat output
and low-temperature regime
(**)
Other items
Standby heat loss
Ignition burner power con-
sumption
Annual energy consumption
Sound power level, indoors
Emission of nitrogen oxides
Water heating energy ef-
ficiency
Daily fuel consumption
Annual fuel consumption
M275V.2428 SM
Yes
No
No
-
Yes
Symbol Value
Unit
η
93
%
s
A
η
88,2
%
4
η
98,1
%
1
P
0,110
kW
stby
P
-
kW
ign
Q
76
GJ
HE
L
53
dB
WA
mg/
NO
28
kWh
x
η
85
%
wh
Q
23,096
kWh
fuel
AFC
18
GJ
See manual cover