ward), until the LCD display shows the
code P06, indicating entry into "parameter
P06" (Fig. 10.21).
Fig. 10.21
• Press the 16 key to show the value of
parameter P06 on the LCD display (Fig.
10.22).
Fig. 10.22
• Press the 16 key and the LCD display
shows the number 01, indicating activa-
tion of the "chimney sweep function" at
minimum output (Fig. 10.23).
• Press the 12 key (Fig. 10.19) to confirm
the value entered and activate the func-
tion.
Fig. 10.23
Flue sweep function at maximum output
in domestic hot water mode
• Press the 16 key and the LCD display
shows the number 01, indicating activa-
tion of the "chimney sweep function" at
minimum output in domestic hot water
mode.
• Press the 12 key (Fig. 10.19) to confirm
MAINTENANCE
RESET
bar
RESET
bar
RESET
bar
the value entered and activate the func-
tion (Fig. 10.24).
Fig. 10.24
Flue sweep function at maximum output
in heating mode
• Press the 16 key and the LCD display
shows the number 03, indicating activa-
tion of the "chimney sweep function" at
maximum output in heating mode.
• Press the 12 key (Fig. 10.19) to confirm
the value entered and activate the func-
tion (Fig. 10.25).
Fig. 10.25
Exiting the chimney sweep function
• To exit the chimney sweep, reset the value
of parameter P06 to 00 or wait 15 minutes
with the boiler switched off (OFF).
• Switch off the boiler by pressing button 17
(Fig. 10.19) until the letters OFF appear
on the LCD display (Fig. 10.26).
Fig. 10.26
RESET
bar
RESET
bar
RESET
bar
- 81 -