Flue Probe And Safety Thermal Fuse - Biasi BASICA COND 28S User Manual And Installation Instructions

Wall hung, fanflue, roomsealed, high efficiency gas boiler
Hide thumbs Also See for BASICA COND 28S:
Table of Contents

Advertisement

n09
(not used)
n11
Flow rate
n14
PWM pump speed
percentage
n15
Fan speed (RPM/100)
n20
(not used)
n21
Last error code
n22
Second-to-last error code
n26
Calculated heating set
point (with climatic curve or
configured set)
n29
Number of weeks to
maintenance
3.8
Flue probe and safety thermal
fuse
If the flue thermal cut-off fuse is
triggered, the boiler goes into
safety lockout. To restore nor-
mal boiler operation, please
contact an Authorized Service
Centre.
The flue probe and safety thermal fuse 17
indicated in Fig. 3.7 are a safety device. The
flue probe 17 intervenes when the flue tem-
perature exceeds 110°C placing the boiler
in safety block switching it off.
To reset normal boiler functioning, just press
the 15 (Fig. 3.5) key.
If flue probe 17 does not intervene and,
therefore does not send the boiler into secu-
rity lockout, flue thermal fuse 17 is triggered
as an additional safety device to protect the
flue outlet pipe.
To restore the normal operation of the boil-
er, contact the Authorized Service Centre.
USEFUL ADVICE
Fig. 3.7
17
- 19 -