Ignition - Biasi BASICA COND User Manual And Installation Instructions

Table of Contents

Advertisement

Fig. 2.3
• Press button 12 (increase) to scroll
through the values the values until the
display shows code n10 "central heating
water pressure" appears on the display
and the pressure value 1.3 bar (Fig. 2.4).
Fig. 2.4
• Open the valves on the filling loop and, at
the same time, check the heating circuit
pressure on the display.
The pressure must be between 1 bar and
1.5 bar (e.g. 1.3 bar in (Fig. 2.4).
Once done, close the valves on the filling
loop.
If you experience any difficulty with the
operation of the boiler, switch off the
boiler immediately at the fused spur iso-
lation switch and contact your Installer
or an approved Service Engineer.
Air introduced into the boiler during this fill-
ing process will vent through the automatic
INSTRUCTIONS FOR USE
RESET
bar
RESET
bar
RESET
bar
air purger fitted to the boiler. You may also
find it necessary to vent air from your radia-
tor circuit using your radiator key, however
be aware that excessive venting will cause
the pressure in the system to drop.
Always ensure that the pressure is set at
the required pressure.
2.3

Ignition

• Check that the valves located in the lower
part of the boiler are open Fig. 2.5.
Open
position
Fig. 2.5
• Power the boiler by turning on the two-
way switch fitted during installation. The
LCD display shows the OFF status (only
the heating and DHW antifreeze functions
are active) Fig. 2.6.
Fig. 2.6
RESET
bar
- 13 -