FLUE TEMPERATURE PROBE NTC AND SAFETY THERMAL FUSE

20 FLUE TEMPERATURE PROBE NTC AND
SAFETY THERMAL FUSE

20.1 Function

The Flue temperature probe NTC A in Figure 20.1 and Figure
20.2 senses the temperature of the combustion products that
ÀRZ WKURXJK WKH FRQGHQVLQJ KHDW H[FKDQJHU
B
A
Figure 20.1
If the temperature of the combustion products circuit reaches the
limit temperature, the Flue temperature probe NTC reduces the
JDV ÀRZ UDWH WR WKH EXUQHU 7KH WHPSHUDWXUH RI WKH FRPEXVWLRQ
products should decrease to a safe value temperature.
In the case that the temperature of the combustion products
reaches a potentially dangerous value, it stops the boiler opera-
tion (lock-out).
7KLV DOORZV WKH XVH RI SODVWLF PDWHULDOV IRU WKH ÀXH RXWOHW SLSHV
and bends.
The use of kits different from the original isn't however allowed,
VLQFH WKH ÀXH SLSHV DUH LQWHJUDO SDUWV RI WKH ERLOHU
A
C
Figure 20.2
A Safety thermal fuse B in Figure 20.1 - Figure 20.2 is also con-
nected in series with the Flue temperature probe NTC and acts
as a safety device in extreme case of incorrect operation of the
Flue temperature control system.
Reaching the breakdown temperature it opens the circuit and
locks out the boiler.
In case of intervention of this safety device the heat exchanger (part
shown in Figure 20.3) may be damaged and must be replaced.
Figure 20.3

20.2 Removal

1 Remove all the case panels.
2 Disconnect the connector C from the Flue temperature probe
3 8QVFUHZ DQG UHPRYH WKH ÀXH WHPSHUDWXUH SUREH A (Figure
4 Assemble the Flue temperature probe NTC carrying out the

20.3 Checks

1 Set the temperature control knobs to their max. position and
2 Allow the boiler to reach its maximum operating temperature
B
1 Remove the Flue temperature probe NTC (see section 20.2).
2 Measure the Flue temperature probe NTC electrical resist-
Warning: isolate the boiler from the mains electrici-
ty supply before removing any covering or compo-
nent.
NTC by pressing the plastic hook placed on the side of the
connector.
20.2) from the condensing heat exchanger.
removal operations in reverse sequence.
Overheat temperature value
run the boiler in d.h.w. and c.h.
(monitor the temperature gauge on the instrument panel).
The boiler should maintain a temperature below that of the
Flue temperature probe NTC and no overheat intervention
should occur.
Temperature-resistance relationship.
ance at the ambient temperature and check it according to
the graph in (Figure 20.4)
- 49 -