• The code A01 appears on the display, in-
dicating entry into "parameter A01" (Fig.
9.4).
Fig. 9.4
• By using buttons 15 or 16 (Fig. 9.3) it is
possible to modify the value of parameter
A01 (Fig. 9.5).
00 = Natural gas (G20)
01 = Propane gas - LPG (G31)
Fig. 9.5
• Press 12 or 13 (Fig. 9.3) to confirm the
value entered and return to the list of pa-
rameters (Fig. 9.4).
• Press the 17 button (Fig. 9.3) to exit "pro-
gramming mode".
• Calibrate the gas valve according to the
GAS CONVERSION
17
16
15
14
RESET
bar
RESET
bar
instructions given in the Service manual,
section Gas valve - Adjustment.
• Reposition the control panel and reas-
semble the front panel of the body.
• Apply the label indicating the type of gas
and the pressure value for which the unit
is set. The self-adhesive label is contained
in the documentation envelope attached
to the boiler.
"Warning if during any PCB re
programming
the power supply to the boiler
you may corrupt the software
setup, ensure you wait at least
10 seconds after any re pro-
gramming before any power iso-
lation event takes place".