Selecting The Maximum Heating Temperature Setpoint With Climatic Curve Set - Biasi BASICA COND User Manual And Installation Instructions

Table of Contents

Advertisement

At this point the system delivery tempera-
ture will follow the trend in relation to the set
K coefficient.
If the room temperature is not comfortable,
you can increase or decrease the heating
system delivery temperature by ± 5°C using
the 15 (decrease) and 16 (increase) buttons
(Fig. 8.9).
With heating temperature setting 25-85°C
(factory preset) the temperature trend for a
K 2.0 is shown in Fig. 8.14, with tempera-
ture setting of 25-55°C the temperature
trend for a K 2.0 is shown in Fig. 8.15 while,
with temperature setting of 50-80°C the
temperature trend for a K 2.0 is shown in
Fig. 8.16.
Delivery
temperature °C
(25-85°C)
90
80
70
+ 5 °C
60
50
40
30
20
25
20
15
10
K=2.0
Fig. 8.14
- 64 -
ADVANCED COMMISSIONING
- 5 °C
5
0
-5
-10
-15
External temperature °C
Delivery
temperature °C
(25-55°C)
60
+ 5 °C
50
40
30
20
25
20
15
K=2.0
Fig. 8.15
Delivery
temperature °C
(50-80°C)
90
80
+ 5 °C
70
60
50
40
30
20
25
20
15
K=2.0
Fig. 8.16
-20
8.4
Selecting the maximum heat-
ing temperature setpoint with
climatic curve set
Depending on the type of high or low tem-
perature heating system, the maximum cli-
matic curve temperature can be set.
The boiler, in heating mode, is set for a tem-
perature regulation a minimum of 25°C to
a maximum of 85°C (factory set), a mini-
mum of 50°C to a maximum of 80°C (high
temperature) or from a minimum of 25°C
to a maximum of 55°C (low temperature).
Please see also "Selecting the heating tem-
perature set" on page 65. For specific
- 5 °C
10
5
0
-5
-10
External temperature °C
- 5 °C
10
5
0
-5
-10
External temperature °C
-15
-20
-15
-20