Fig. 8.40
• By using buttons 15 or 16 (Fig. 8.31) it is
possible to modify the value of parameter
A01 (Fig. 8.41).
00 = Natural gas (G20)
01 = Propane gas - LPG (G31)
Fig. 8.41
• Press 12 or 13 (Fig. 8.31) to confirm the
value entered and return to the list of pa-
rameters (Fig. 8.40).
• Press 12 and hold until the LCD display
shows the code A02, indicating entry into
"parameter A02" (Fig. 8.42).
Fig. 8.42
• By using buttons 15 or 16 (Fig. 8.31) it is
possible to modify the value of parameter
A02:
01 = high temperature (50/80°C)
02 = low temperature (25/55°C)
03 = full range temperature set (25/85°C)
(factory setting)
- 70 -
ADVANCED COMMISSIONING
RESET
bar
RESET
bar
RESET
bar
• Press 12 or 13 (Fig. 8.31) to confirm the
value entered and return to the list of pa-
rameters (Fig. 8.42).
• Press button 12 and hold until the LCD
display shows the code A12, indicating
entry into "parameter A12" (Fig. 8.43).
Fig. 8.43
• By using buttons 15 or 16 (Fig. 8.31) it is
possible to modify the value of parameter
A12 (Fig. 8.44).
03 = Default
04 = Correct
Fig. 8.44
• Press button 12 and hold until the LCD
display shows the code A21, indicating
entry into "parameter A21" (Fig. 8.45).
Fig. 8.45
• By using buttons 15 or 16 (Fig. 8.31) it is
possible to modify the value of parameter
A21 (Fig. 8.46).
00 = Room thermostat
01 = Remote control
RESET
bar
RESET
bar
RESET