Biasi BASICA COND User Manual And Installation Instructions page 49

Table of Contents

Advertisement

Roof flue exhaust kit (Fig. 6.9)
This kit exhausts directly to the roof.
Coaxial pipe
Nominal height
Maximum height
Type C
33
Fig. 6.9
Extensions are available for reaching the
maximum height.
Bends at 90° and at 45° are available that
reduce the maximum total length of the
pipes by:
For the bend of 45° loss
For the bend of 90° loss
Pluming kit A (Fig. 6.10)
Coaxial Ø 60/100 mm + vertical part Ø 60
mm (flue outlet).
Coaxial Ø 60/100 mm (b) + vertical part
Ø 60 mm (a)
Telescopic coaxial flue
Maximum length (a + b)
This kit allows the products of combustion
to be discharged at a different location to
the air intake to avoid nuisance issues.
INSTALLATION
Ø 60/100
Ø 80/125
mm
mm
0.96 m
0.96 m
10 m
12 m
0.5 m
1 m
0.45-0.95 m
15 m
90° =--- 0,85 m
45° =--- 0,65 m
90°
45°
Fig. 6.10
60 mm elbows and extensions can be add-
ed to the vertical section.
Each additional elbow reduces the overall
acceptable length of the flue system as fol-
lows:
For the bend of 45° (60/100 mm) loss 0.5 m
For the bend of 90° (60/100 mm) loss
For the bend of 45° (60 mm) loss
For the bend of 90° (60 mm) loss
Pluming kit B (Fig. 6.11) (Fig. 6.12)
Push on type Ø 60 mm vertical plume man-
agement kit
This kit allows the products of combustion to
be discharged at a different location, when
used with the standard horizontal flue kit.
ø 60 mm
90° =--- 1 m
ø 60/100 mm
45° =--- 0,5 m
1 m
0.65 m
0.85 m
- 49 -