Remote Fault Code; Flue Gas Probe And Thermal Fuse - Biasi RINNOVA ADAPTIVE 25S User Manual And Installation Instructions

Table of Contents

Advertisement

Figure 3.10
To scroll through the values, press the 13 key
(previous INFO) and 15 key (next INFO).
To exit INFO mode, simply:
• wait 15 minutes without pressing any key;
• switch off the electric power supply;
• press and hold the 13 and 15 keys simulta-
neously for 5 seconds (Figure 3.9) (one level
up).
The table summarises the possible values visi-
ble in INFO mode.
Value shown
Primary circuit pressure
Outdoor temperature
K curve value configured on
site
Offset climatic curve value
Calculated heating set point
(with climatic curve or set
configured)
Delivery NTC temperature
Return NTC temperature
DHW set
DHW inlet temperature (if
foreseen)
DHW outlet temperature
DHW capacity
USEFUL TIPS
Flue gas temperature
(if foreseen)
Fan speed
Flue gas pressure transducer
(if foreseen)
Ionisation current value
Number of months to main-
tenance
3 star status
(ON=01, OFF=00)
Modulation percentage
Pump modulation percent-
age
Delivery 2 temperature
(if foreseen)
M.B. version
Main SW version

3.8 Remote fault code

If the optional remote is connected to the boil-
er, a code can be shown on the central part of
the display that indicates a boiler anomaly.
The current anomaly is indicated by a numeric
code followed by the letter E.
Table of
The anomaly codes sent to the remote are the
contents
same as those shown on the display (see "LCD
J00 + value
SIGNALS" on page 8).
J01 + value
J02 + value
3.9
J03 + value
J04 + value
J05 + value
The flue gas probe and thermal fuse 18 indicat-
J06 + value
ed in Figure 3.11 are safety devices.
The flue gas probe and 18 are triggered when
J07 + value
the flue gas temperature exceeds 110°C, acti-
J08 + ---
vating the boiler safety lockout, shutting it off.
To reset normal boiler operation simply press
J09 + value
the button 14 (Figure 3.9).
J10 + value

Flue gas probe and thermal fuse

Thermofuse tripping involves a
safety lockout, and requires reset-
ting by an Authorised Service Cen-
tre.
J11 + ---
J12 + value
J13 + ---
J14 + value
J15 + value
J16 + value
J17 + value
J18 + value
J19 + value
J20 + value
J21 + value
- 19 -