Hitachi L100 Instruction Manual page 53

L100 series
Hide thumbs Also See for L100:
Table of Contents

Advertisement

2–22
Selecting Functions and Editing Parameters
Toll Free: voice: 1-877-539-2542 fax: 1-800-539-2542 www.mgitech.com
Technologies Inc.
Using the Front Panel Keypad
In order to run the motor for the powerup test, this section will show how to:
• select the inverter's maximum output frequency to the motor
• select the keypad potentiometer as the source of motor speed command
• select the keypad as the source of the RUN command
• enable the RUN command
The following series of programming tables are designed for successive use. Each table
uses the previous table's final state as the starting point. Therefore, start with the first and
continue programming until the last one. If you get lost or concerned that some of the
other parameters settings may be incorrect, refer to the section on restoring factory
default settings on page 6–8.
CAUTION: If you operate a motor at a frequency higher than the inverter standard
default setting (50Hz/60Hz), be sure to check the motor and machine specifications with
the respective manufacturer. Only operate the motor at elevated frequencies after getting
their approval. Otherwise, there is the danger of equipment damage.
Setting the Motor Base Frequency -The motor is designed to operate at a specific AC
frequency. Most commercial motors are designed for 50/60 Hz operation. First, check
the motor specifications. Then follow the steps in the table below to verify the setting or
correct for your motor. DO NOT set it for greater than 50/60 Hz unless the motor
manufacturer specifically approves operation at the higher frequency.
Action
key.
Press the
FUNC.
or
keys until ->
Press the
2
1
key.
Press the
FUNC.
key twice.
Press the
1
key.
Press the
FUNC.
or
key as needed.
Press the
2
1
STR
key.
Press the
TIP: If you need to scroll through a function or parameter list, press and hold the
key to auto-increment through the list.
2
Display
Func./Parameter
Monitor functions
D
01
"A" group selected
A
- -
First "A" parameter
A
01
Base frequency setting
A
03
Default value for base frequency.
60
US = 60 Hz, Europe = 50 Hz.
or
50
Set to your motor specs (your
60
display may be different)
Stores parameter, returns to "A"
A
03
group list
or
1