General Warnings and Cautions
General Caution
Toll Free: voice: 1-877-539-2542 fax: 1-800-539-2542 www.mgitech.com
Technologies Inc.
CAUTION: EFFECTS OF DISTRIBUTOR LINES ON INVERTERS
EMI filter
Inverter
R1
R2
L1(L1)
Power
S1
S2
L2
source
T1
T2
L3(N)
In the cases below involving a general-purpose inverter, a large peak current flows on the
power supply side, sometimes destroying the converter module. Where such situations
are foreseen, or the paired equipment must be highly reliable, install an AC reactor
between the power supply and the inverter.
1. The unbalance factor of the power supply is 3% or higher.
2. The power supply capacity is at least 10 times greater than the inverter capacity (and
the power supply capacity, 500 kVA or more).
3. Abrupt power supply changes are expected.
Some examples include:
a.Several inverters are interconnected with a short bus.
b.A thyristor converter and an inverter are interconnected with a short bus.
c:An installed phase advance capacitor opens and closes.
In cases (1), (2), and (3) we recommend installing an AC reactor of 3% (at a voltage
drop at rated current) with respect to the supply voltage on the power supply side.
CAUTION: When the EEPROM error E8 occurs, be sure to confirm the setting value
again.
CAUTION: When setting b contact to the forward or reverse command [FW], [RV]
terminal, the inverter starts automatically. Do not set to b contact without a purpose.
CAUTION: In all the illustrations in this manual, covers and safety devices are
occasionally removed to describe the details. While operating the product, make sure
that the covers and safety devices are placed as they were specified originally and
operate it according to the instruction manual.
Power
Motor
U
U
source
V
V
W
W
EMI
Terminal
filter
for
grounding
Noise
Motor
Inverter
Ground the
frame.
Piping
Noise
(to be grounded)
or shielded wire
Completely ground the shield made
of metal screen, enclosed panel, etc.
with as short a wire as possible.