3–30
Option
Code
15
16
18
19
Toll Free: voice: 1-877-539-2542 fax: 1-800-539-2542 www.mgitech.com
Technologies Inc.
"C" Group: Intelligent Terminal Functions
Input Function Summary Table
Terminal
Function Name
Symbol
SFT
Software Lock
AT
Analog Input
Voltage/current
Select
RS
Reset Inverter
PTC
PTC Thermistor
Thermal Protection
Description
ON
The keypad and remote programming
devices are prevented from changing param-
eters
OFF
The parameters may be edited and stored
ON
Terminal OI is enabled for current input
(uses terminal L for power supply return)
OFF
Terminal O is enabled for voltage input (uses
terminal L for power supply return)
ON
The trip condition is reset, the motor output
is turned off, and powerup reset is asserted
OFF
Normal power-on operation
ANLG When a thermistor is connected to terminals
5 and L, the inverter checks for over-
temperature and will cause trip event and
turn off output to motor
OPEN A disconnect of the thermistor causes a trip
event, and the inverter turns off the motor