Error
Name
Code
E35
PTC error
NOTE: If an EEPROM error (E08) occurs, be sure to confirm the parameter data values
are still correct. If the power is turned off while the [RS] (Reset) intelligent input
terminal is On, an EEPROM error will occur when power is restored.
Cause(s)
When intelligent terminal 5 is configured for PTC
(protective thermistor) function and the inverter has
sensed the resistance is too high (wire is broken or
temperature is too high), the inverter trips and turns
off the output.
6–7