Hitachi L100 Instruction Manual page 70

L100 series
Hide thumbs Also See for L100:
Table of Contents

Advertisement

3–14
Func.
Code
A41
Torque boost method
selection
A42
Manual torque boost
value
A43
Manual torque boost
frequency adjustment
A44
V/F characteristic
curve selection
A45
V/F gain setting
Toll Free: voice: 1-877-539-2542 fax: 1-800-539-2542 www.mgitech.com
Technologies Inc.
"A" Group: Standard Functions
The following table shows the methods of torque control selection.
"A" Function
Name
Two options:
00 ...Manual torque boost
01 ...Automatic torque boost
Can boost starting torque
between 0 and 99% above
normal V/F curve, from 0 to
1/2 base frequency
Sets the frequency of the V/F
breakpoint A in graph (top of
previous page) for torque boost
Two available V/F curves;
three select codes:
00 ...Constant torque
01 ...Reduced torque
Sets voltage gain of the inverter
from 20 to 100%
Run-
time
Description
Edit
Defaults
DOP,DRW,DOP+
EU/
Func.
Units
Name
US
Code
00
F-50
V-BOOST
MODE
11
F-50
V-BOOST
CODE
10
%
F-50
V-BOOST
F
0
F-04
Control
100
%
Mon.
V-GAIN

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents