DC Braking Settings
Func.
Code
A51
A52
A53
A54
A55
Toll Free: voice: 1-877-539-2542 fax: 1-800-539-2542 www.mgitech.com
Technologies Inc.
The DC braking feature provides
additional stopping power when compared
to just a normal deceleration to a stop. DC
braking is particularly useful at the low
frequency end of the deceleration ramp
where there is little or no motor torque
available for stopping. If you enable DC
braking, it turns on during deceleration at a
frequency you can specify. If desirable,
you can specify a delay time during which the motor coasts (free runs) before DC
braking helps stop the rotation.
Most importantly, the force and duration of DC braking are adjustable. Be careful to not
specify a long braking time that causes motor overheating. If you use DC braking, we
recommend using a motor with a built-in thermistor, and wiring it to the inverter's
thermistor input (see page 4–17). Also refer to the motor manufacturer's specifications
for duty-cycle recommendations during DC braking.
"A" Function
Name
DC braking enable
Two options; select codes:
00... Disable
01... Enable
DC braking frequency
The frequency at which DC
setting
braking occurs,
range is 0.5 to 10 Hz
DC braking wait time The delay from the end of Run
command to start of DC
braking (motor free runs until
DC braking begins)
DC braking force
Applied level of DC braking
setting
force, settable from 0 to 100%
DC braking time
Sets the duration for DC
setting
braking, range is 0.1 to 60.0
seconds
+
Running
0
Run-
time
Description
Edit
3–15
L100 Inverter
Free run
DC braking
time
A53
A55
Defaults
DOP,DRW,DOP+
EU/
Func.
Units
Name
US
Code
00
F-20
DCB SW
0.5
Hz
F-20
DCB F
0.0
sec.
F-20
DCB
WAIT
0
%
F-20
DCB V
0.0
sec.
F-20
DCB T