Hitachi L100 Instruction Manual page 75

L100 series
Hide thumbs Also See for L100:
Table of Contents

Advertisement

Second Acceleration and Deceleration Functions
Func.
Code
A92
A93
A94
A95
Toll Free: voice: 1-877-539-2542 fax: 1-800-539-2542 www.mgitech.com
Technologies Inc.
The L100 inverter features two-stage acceleration and deceleration ramps. This gives
flexibility in the profile shape, and can avoid jerk (mechanical shock) while approaching
steady frequency (or stop) more gently. You can specify the frequency transition point,
the point at which the standard acceleration (F02) or deceleration (F03) changes to the
second acceleration (A92) or deceleration (A93). Select a transition frequency method
via A94 as depicted below.
frequency
A94 = 00
Accel 2
Accel 1
1
2CH
input
0
Standard acceleration and deceleration is
linear. The inverter CPU can also calculate
an S-curve acceleration and deceleration
curve as shown. This profile avoids abrupt
changes in velocity, to reduce shock to the
motor load. The CPU fits the S-curve
acceleration or deceleration to a time
period you specify. It is also possible to
have a linear acceleration and an S-curve
deceleration, for example.
To enable the S-curve, use function A97 (acceleration) and A98 (deceleration).
"A" Function
Name
Second acceleration
Duration of 2nd segment of
time setting
acceleration, range is:
0.1 to 3000 sec.
Second deceleration
Duration of 2nd segment of
time setting
deceleration, range is:
0.1 to 3000 sec.
Select method to use
Two options for switching
second accel/decel
from 1st to 2nd accel/decel:
00... 2CH input from terminal
01... transition frequency
Acc1 to Acc2
Output frequency at which
frequency transition
Accel1 switches to Accel2,
point
range is 0.0 to 360.0 Hz
frequency
A95
time
0
frequency
Target
freq.
Linear
0
Acceleration period
Run-
time
Description
Edit
3–19
L100 Inverter
A94 = 01
Accel 2
Frequency
transition point
Accel 1
time
Accel. curve
A97
S-curve
time
Defaults
DOP,DRW,DOP+
EU/
Func.
Units
Name
US
Code
15.0
sec.
F-06
ACC2
15.0
sec.
F-07
DEC 2
00
F-06
ACC
CHG
0.0
Hz
F-06
ACC
CHFr

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents