No Power To Part Of Controller Module; Table 4-7 No Power To Part Of Controller Module - Sun Microsystems Sun StorEdge A3500 Manual

Hide thumbs Also See for Sun StorEdge A3500:
Table of Contents

Advertisement

4.3.2

No Power to Part of Controller Module

TABLE 4-7
Symptom
Front panel Power
LED off (all other
canister power
LEDs on)
Both power supply
Power LEDs on (all
other Power LEDs
off)
One power supply
Power LED is on,
the other is off.
No Power to Part of Controller Module
Possible Causes
Controller fan missing or not
inserted all the way
Controller fan circuitry failure
Canisters not inserted
DC power harness failure
Power interface board failure
Controller back panel failure
Power supply turned off or
disconnected
Power supply overheated
Power supply failure
Corrective Action
Make sure controller fan is installed
correctly. If LED still off, it may be
burned out. Go to next cause.
Replace controller fan.
Make sure all the controllers and fans
are locked securely in place.
Replace the DC power harnesses (call
service technician).
Replace the power supply housing
(call service technician).
Replace the controller card cage (call
service technician).
Check power cord and turn on the
power switch. If canister LED remains
off, go to Cause next cause.
Wait 10 minutes to see if power
supply turns on again. If not, go to
next cause.
Check for power supply Fault LED on
front panel. If lit, replace failed power
supply.
Chapter 4
Diagnostics and Troubleshooting
Reference
page 8-3
page 7-8
page 7-11
page 6-10
page 3-2
page 7-2
page 7-4
4-11