Figure 7-8 Power Supply Housing Connectors - Sun Microsystems Sun StorEdge A3500 Manual

Hide thumbs Also See for Sun StorEdge A3500:
Table of Contents

Advertisement

3. Unpack and install the new power supply housing.
a. With the connector side of the power supply facing the rear shield, set the
housing into the chassis (
Connectors for
power harnesses
Power Supply Housing Connectors
FIGURE 7-8
b. Slide the housing forward until you can reconnect the DC power harnesses.
After you reconnect both harnesses, push the power supply housing in the rest of
the way.
c. Replace the eight mounting screws (
4. Replace the controller module in the cabinet.
See Section 5.2.2 "Replacing the Controller Module" on page 5-7.
5. Reconnect the controller module power cords.
6. Reconnect the SCSI or fibre optic cables to the controller module.
7. Power on the system and check the LEDs.
See Section 3.1 "Powering On the Controller Module and System" on page 3-2. If a
Fault LED is lit, or if the Power LEDs remain off, see Section 4.2 "Checking the
Battery Label" on page 4-9 for troubleshooting procedures.
8. Use RAID Manager software to check the status of the controller module.
Refer to the Sun StorEdge RAID Manager 6.22 User's Guide for instructions.
).
FIGURE 7-8
Rear
FIGURE 7-6
).
Chapter 7
Power Subassemblies
7-13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sun storedge a3500fcStoredge a3000

Table of Contents