Built-In Ring Lights - Siemens SIMATIC MV500 Operating Instructions Manual

Hide thumbs Also See for SIMATIC MV500:
Table of Contents

Advertisement

13.3.2

Built-in ring lights

Note
Achievement of IP67 protection
To achieve IP67 degree of protection, a protective lens barrel must be screwed on and all
interfaces must be closed by cable connections or protective caps.
If no protective lens barrel is used or the interfaces are closed, the reader only achieves IP20
degree of protection.
Note
Compatibility of the built-in ring lights for SIMATIC MV440
Note that SIMATIC MV440 built-in ring lights are compatible with SIMATIC MV500 optical
readers. However, using the MV440 built-in ring lights on MV500 does not support the micro
SD card and E-focus function.
Table 13- 5
Built-in ring light
Built-in ring light (red, basic) for
SIMATIC MV500
Built-in ring light (red, far) for
SIMATIC MV500
Built-in ring light (red, multi) for
SIMATIC MV500
Built-in ring light (white, multi) for
SIMATIC MV500
SIMATIC MV500
Operating Instructions, 03/2021, C79000-G8976-C494-05
Built-in ring lights for SIMATIC MV500
Description
Scope of delivery and ordering data
Light source: LED red
(625 nm)
Lighting distance up to 0.8 m
Including anti-glare attachment
Light source: LED red
(625 nm)
Lighting distance up to 3.0 m
Including anti-glare attachment
Light source: LED red
(625 nm)
Lighting distance up to 1.5 m
including attachment with polarization
filter
Including anti-glare attachment
Light source: LED white
(6500 K)
Lighting distance up to 1.5 m
including attachment with polarization
filter
Including anti-glare attachment
13.3 Accessories
Article number
6GF3540-8DA11
6GF3540-8DA12
6GF3540-8DA13
6GF3540-8DA33
265