Mounting With Built-In Ring Light And Ef Lens - Siemens SIMATIC MV500 Operating Instructions Manual

Hide thumbs Also See for SIMATIC MV500:
Table of Contents

Advertisement

5.3

Mounting with built-in ring light and EF lens

Mounting the optical reader in conjunction with an EF lens (Electronic Focus Lens) is done in
two steps:
1. Disassembling the built-in ring light
2. Mounting the individual components
Disconnecting SIMATIC MV500 from the power supply
Make sure that the power supply is switched off when installing/uninstalling the devices as
well as the internal ring light, EF lens and micro SD adapter.
Disassembling the built-in ring light
Figure 5-3
Follow the steps below to disassemble the built-in ring light:
1. If necessary, remove the connection board ① from the ring light ③.
2. Loosen the ring light from the ring light holder by unhooking the ring light ③ from the ring
light holder ②.
SIMATIC MV500
Operating Instructions, 03/2021, C79000-G8976-C494-05
CAUTION
Disassembling the built-in ring light
5.3 Mounting with built-in ring light and EF lens
Mounting
107

Advertisement

Table of Contents
loading

Table of Contents