Siemens SIMATIC MV500 Operating Instructions Manual page 27

Hide thumbs Also See for SIMATIC MV500:
Table of Contents

Advertisement

Compatibility with MV400
The functions, communication protocols and configurations are largely compatible with the
devices of the SIMATIC MV400 series. The device configurations for these devices can be
imported into the readers of the SIMATIC MV500, enabling a seamless transition from
SIMATIC MV400 to MV500.
Note that after importing an MV400 device configuration, the program must be saved again.
Table 1- 1
Digital inputs
/outputs
RS232 interface
DISA bit (via)
DHCP modes
WebAPI
The MV400 "Resolution, half" function is no longer available on MV500 due to faster image
acquisition times.
NOTICE
Compatibility restrictions
Note that the following functions are not supported by MV400 in the software versions ≤
V2.0:
• Calibrated verification (Veri-Genius license),
• Vericode
• OCR (Text Genius) and
• Locator function (Pat genius)
SIMATIC MV500
Operating Instructions, 03/2021, C79000-G8976-C494-05
Differences / possible incompatibilities
RS232, CM, TCP/IP, PN, DI
SIMATIC MV400
DI trigger, DQ strobe,
4 configurable DI/DQs
9.6 ... 115 KB
1 ◆ 1.5 ◆ 2 stop bits
Client and server
Description
1.7 Functional description
SIMATIC MV500
DI trigger, DQ strobe,
2 DQs
9.6 ... 115 KB
1 ◆ 2 stop bits
RS232, CM, TCP/IP, PN
Client
(CONNECT button)
(incompatible with MV400)