Siemens SIMATIC MV500 Operating Instructions Manual page 230

Hide thumbs Also See for SIMATIC MV500:
Table of Contents

Advertisement

Service and maintenance
10.1 Error and diagnostics messages
Error code
Error message
(%c)
(%s)
0014
Found m instead of the expected number of
1D/2D codes in step n
0015
Maximum number of codes per image (m) was
exceeded in step n
0016
The maximum amount of data which can be de-
coded was exceeded in code m of step n
0017
Trigger during image acquisition
0018
Step timeout reached in step n
1006
No text found in step n
1007
Text length is less than minimum specified in step
n
1008
Text length exceeds the maximum specified in
step n
1009
Quality violates limit values in step n
1010
Match failed in step n
1011
Reference text missing in step n
4700
Verification failed in step n
4701
Verification for code type found in step n not
supported
4707
Mean light outside of range in step n: Maximum
exposure time reached
4708
Mean light outside of range in step n: Cycle time
limit of the automatic exposure control reached
4709
Mean light outside of range in step n
230
Description
Only m codes instead of the expected number of
codes were found in step # n during multicode decod-
ing.
More than the maximum possible number of codes per
image was found with multicode decoding (50,
MV500 U: 150).
A maximum of 3001 bytes can be decoded per step.
This length was exceeded in step #n for code #m.
The trigger signal was applied during image acquisi-
tion. In this case, no additional image acquisition is
started. Instead, image acquisition and processing are
continued and an "N_OK" result is generated immedi-
ately upon completion.
In step #n, the defined time limit was reached.
OCR: No text was found in step #n.
OCR: The text found in step #n is shorter than the
minimum setting.
OCR: The text found in step #n is longer than the max-
imum setting.
OCR: The text found in step #n is below the quality
threshold setting.
OCR: The match performed in step #n was not success-
ful.
OCR: There is no string specification available for
step #n.
The read code could not be verified.
The selected verification method is not supported for
the code type found in step #n.
The average brightness needed for ISO/IEC 29158 is
outside the valid range (see Error code 4709).
The specified maximum value for the exposure time
was reached during automatic exposure control.
To resolve this error:
1. Use brighter lighting or enlarge the aperture of the
objective (lower aperture number).
2. Perform a new calibration.
The average brightness needed for ISO/IEC 29158 is
outside the valid range (see Error code 4709).
The automatic exposure control was unsuccessful
because the necessary decodings could not be com-
pleted within the time limit.
To resolve this error:
Reduce the exposure ROI of the program.
Increase the time limit of the exposure control.
Also ensure that the code is completely within the
exposure ROI until conclusion of the image acquisi-
tion process.
The average brightness needed for ISO/IEC 29158 is
outside the valid range (70% to 86%) in step #n.
Operating Instructions, 03/2021, C79000-G8976-C494-05