The "DONE" parameter then has the value "TRUE" and "ACTIVE" the value "FALSE".
Note
No edge change detected
Because the job completes in one CPU cycle, no edge change can be detected at the "ACTIVE"
parameter. If the "DONE" parameter already has the value "TRUE" from a previous job, it is
also not possible to detect an edge change.
Sequence when resetting the DISA bit ("COMMAND" = W#16#0005)
The block resets the "DISA" bit in the control byte of the optical reader. The "DONE" parameter
then has the value "TRUE" and "ACTIVE" the value "FALSE".
Note
No edge change detected
Because the job completes in one CPU cycle, no edge change can be detected at the "ACTIVE"
parameter. If the "DONE" parameter already has the value "TRUE" from a previous job, it is
also not possible to detect an edge change.
Sequence of the read jobs ("COMMAND = W#16#0081 ... W#16#008F")
Table 9- 48
Value (W#16#...) Meaning
0081
0082
0083
0084
0085
0086
0087
0088
0089
008A
008B
008C
008D
008E
008F
The read jobs can only be sent when the optical reader is not in RUN mode (see also the
operating state table following the parameter table).
SIMATIC MV500
Operating Instructions, 03/2021, C79000-G8976-C494-05
Possible values of the "COMMAND" parameter for the read jobs
Output result string
Output absolute quality characteristics
Output absolute quality characteristics and output result string
Output quality characteristics as classes
Output quality characteristics as classes and output result string
Output quality characteristics as classes and in absolute format
Output quality characteristics as classes and in absolute format and output result
string
Output code position
Output code position and result string
Output code position and output absolute quality characteristics
Output absolute code position and quality characteristics and output result string
Output code position and quality characteristics as classes
Output code position and quality characteristics as classes and output result string
Output code position and quality characteristics as classes and in absolute format
Output code position and quality characteristics as classes and in absolute format
and output result string
Process interfacing via an automation system (PLC, PC)
9.4 Control with FB 79
193