Process interfacing via an automation system (PLC, PC)
9.10 Example programs
Area: Output
"Save Bitmaps to ..." and "Save CSV files to ...":
• Specify the storage path under which the diagnostic images and CSV files are saved.
"Bitmap Filename Template" and "CSV Filename Template":
In these input boxes, you can define specifications for naming the generated files.
You can use the following placeholders:
• %Date%
Is replaced with the current date or the date stamp of the image acquisition in the "Year-
Month-Day" format.
• %Time%
Is replaced with the current time or the time stamp of the image acquisition in the "Hours-
Minutes-Seconds-Milliseconds" format.
• %DeviceType%
Replaced by the device type of the connected optical reader, e.g. "MV540-H".
• %Uid%
Replaced by a random unique ID of the image (24 digits).
Use a backslash ("\") to define subfolders. The subfolders are created below the output
folders.
"max. Entries per CSV"
• In the input box, enter the maximum number of lines a CSV file is to contain.
A new CSV file is created as soon as the maximum number of lines is exceeded.
Area: Control
In this area, you can establish/terminate the connection to the reader and start/stop the
transmission of the diagnostic data.
Click the "Open Connection" button to set up the connection between the PC and the optical
reader. After the optical reader has established the connection with the PC, start sending the
diagnostic data by clicking the "Start Recording" button.
Note
Connection cannot be set up
If the optical reader cannot set up a connection to the PC, the message "Waiting for
Connection..." appears on the screen.
First check whether the connection settings are configured correctly in the example program
and in the optical reader. Check the firewall settings if the optical reader cannot set up a
connection despite correct configuration.
In this case, contact the network administrator, if necessary.
To stop transferring the diagnostic data, click on the "Stop Recording" button. Click the
"Close Connection" button to terminate the connection between the PC and the optical
reader.
220
Operating Instructions, 03/2021, C79000-G8976-C494-05
SIMATIC MV500