Connecting cable for external ring lights
Figure 6-6
Table 6- 5
Pin
1
2
3
4
6.4
Wiring examples
I/O interface
Wire the "Output Common" signal with + 24 V DC and the "Input Common" signal with 0 V.
Figure 6-7
Wire the "Output Common" signal with 0 V and the "Input Common" signal with + 24 V DC.
SIMATIC MV500
Operating Instructions, 03/2021, C79000-G8976-C494-05
Pin assignment connecting cable plug
Connecting cable for external ring lights M12 (male, 4-pin) / open end
Wire color
SIMATIC MV500 signal
Brown
24 V DC power supply
White
Trigger input
Blue
NC
Black
Ground
I/O interface as P type
Connection
6.4 Wiring examples
123