Siemens SIMATIC MV500 Operating Instructions Manual page 219

Hide thumbs Also See for SIMATIC MV500:
Table of Contents

Advertisement

Operation of the example program
Start the example program by double-clicking "MMIDiagnosticsGUI.exe".
Area: Connection
Apply the entries for the IP address and port that you have configured under "Settings >
Communication > Interfaces > Archiving/MMI" in the WBM.
• Select the IP address from the "Local IP Address" drop-down list.
• Enter the port in the "Port" text box.
• Enter the desired time in the "Timeout [sec]" text box.
If the example program has not received a response from the optical reader for the
specified amount of time, the example program terminates the connection to the optical
reader.
Enter the value "0" in the input box to disable Timeout monitoring.
SIMATIC MV500
Operating Instructions, 03/2021, C79000-G8976-C494-05
Process interfacing via an automation system (PLC, PC)
9.10 Example programs
219

Advertisement

Table of Contents
loading

Table of Contents