Siemens SIMATIC MV500 Operating Instructions Manual page 66

Hide thumbs Also See for SIMATIC MV500:
Table of Contents

Advertisement

Image processing
3.2 Code verification
Verification report
Through the input of "%R" in the format string, you receive a verification report containing
the overall quality and information on the lighting used. The precise formatting and the
values contained depend on the verification standard that was used and are defined in the
specific standard.
Note
Availability of the verification report
Values enclosed in square brackets are optional.
The verification report is not available for verification according to ISO/IEC 16022, AS 9132
Rev. A and Siemens DPM.
• Output for ISO/IEC 15415:
<overall grade>/<aperture or cell size>/<wavelength>/[<radiation angle ≠ 45°>]
• Output for ISO/IEC 29158:
DPM<overall grade>/<percentage aperture>/<wavelength>/[<radiation angle ≠ 45°>]
• Output for ISO/IEC 15416:
<overall grade>/<module size>/<wavelength>/
Verification settings
Through the input of "%v" in the format string, you receive an output of all output parameters
relevant for verification in the printed order.
All field values are separated by semicolons. The field names are not part of the report.
Table 3- 9
Field name
Exposure time
Brightness
Brightness offset (coarse)
Brightness offset (fine)
Histogram peak low
Histogram peak high
Cell scaling * 100
Target contrast
Maximum reflectance
Minimum X dimension
Maximum X dimension
Avg. gray scale value
Calibrated exposure time
Calibrated brightness
Light source
Radiation angle
66
Output parameters of the verification
Value
0000 ... 9999
0000 ... 0999
-255 ... 0255
-25 ... 0255
0000 ... 0255
0000 ... 0255
0000 ... 9999
0000 ... 0100
0000 ... 0100
0000 ... 0999
0000 ... 0999
0000 ... 0255
0000 ... 9999
0000 ... 0999
Name of the lamp
0000 ... 9999
Operating Instructions, 03/2021, C79000-G8976-C494-05